Get free quotes

Free pump calculator

Borehole and water pump troubleshooting

Pick what the pump is doing to see the likely causes, what a technician checks, and which service to ask for. Switch the power off at the board before touching the pump, the box or the tank.

What is the pump doing?

Electrical work on a pump, a control box or a borehole cable must be done by a qualified electrician.

The pump runs but gives no water, or very little

  1. The water level has dropped to the pump. In a dry spell or after long pumping, the borehole can fall below the pump. The motor then runs light and hot. A technician measures the level with a dip meter; the fix is to pump less, hang the pump deeper or fit dry-run protection.
  2. A split drop pipe or a loose joint. The water leaks back down the hole before it reaches the top. The pump has to be pulled to find it.
  3. Worn impellers or a blocked inlet. Sand wears the stages and the flow falls off over months; a clogged inlet screen does the same quickly.
  4. A stuck non-return valve or a closed valve. Check the valves on the surface first, then the non-return valve at the pump.
  5. A three phase motor turning backwards. It runs, but gives a fraction of its flow. An electrician swaps two of the phases.

Ask for: Borehole Pump Repairs, Pump Spares

The pump hums but won't start

  1. A failed capacitor. Single phase pumps with a control box need a start and often a run capacitor. A failed capacitor is one of the commonest faults, and it is cheap to replace.
  2. Low voltage at start. A long or thin cable, or a weak supply, drops the voltage too far when the motor starts. See the cable calculator.
  3. The pump is jammed with sand. After standing for a while, sand can lock the stages. It usually has to come out.
  4. A damaged motor or cable. An insulation test of the motor and the cable from the surface tells a technician whether the fault is down the hole.

Ask for: Pump Control Boxes, Pump Spares, Borehole Pump Repairs

It trips the earth leakage or the breaker

  1. Water in the cable, the splice or the motor. The commonest reason for an earth leakage trip on a borehole. Do not keep resetting it: an electrician tests the insulation of the cable and the motor.
  2. A shorted motor winding. The motor may need a rewind or replacing. See water pump repairs.
  3. A breaker or overload that does not match the motor. The protection must suit the motor's full load current, and the overload must be set to the nameplate.

Ask for: Pump Control Boxes, Water Pump Repairs, Borehole Pump Repairs

It starts and stops every few seconds

  1. The pressure tank has lost its air or its membrane has burst. With the pump off and the tank drained, the air pressure should be about 0.2 bar under the cut-in. If water comes out of the air valve, the membrane has failed.
  2. A leaking non-return valve. Water runs back down the pipe and the pressure falls as soon as the pump stops.
  3. A leak in the plumbing. A dripping tap, a running toilet or a leak underground drops the pressure all the time.
  4. The tank is too small or the switch is set too close. See the pressure tank calculator.

Ask for: Pressure Tanks, Pump Spares, Booster Pumps

It runs and won't switch off

  1. It can't reach the cut-out pressure. A worn pump, a leak, or a cut-out set higher than the pump can make. The pump runs on with nothing to show for it.
  2. A faulty pressure switch or float switch. Contacts weld closed, or the float hangs up on the pipe or the tank wall.
  3. The water level has fallen. The pump can no longer lift high enough to reach the cut-out pressure.

Ask for: Pump Spares, Pressure Tanks, Borehole Pump Repairs

The pressure at the taps is low

  1. The pump is too small for the head. Check the total head with the borehole sizing calculator against the pump's curve.
  2. A pipe that is too small or too long. Friction eats the pressure. See the pipe friction calculator.
  3. A blocked filter or a part-closed valve. Filters on the line clog with sand and iron.
  4. A worn pump. Flow and pressure fall off slowly over the years, especially in sandy holes.

Ask for: Booster Pumps, Pressure Tanks, Water Pump Repairs

Sand, mud or air comes out with the water

  1. The pump is set too close to the bottom. It draws in silt from the bottom of the hole. Raise it.
  2. Pumping more than the yield. Fast drawdown pulls sand through the formation and lets air in at the pump inlet. Pump less, over more hours.
  3. A damaged casing or screen. A collapsing hole may need the driller to clean or reline it.
  4. A hole in the drop pipe near the top. Air gets drawn in and the water spits.

Ask for: Borehole Drilling, Borehole Pump Repairs

It trips on overload after running a while

  1. The motor is overheating. Submersible motors are cooled by the water flowing past them. A pump hung below the water entry with no cooling sleeve, or one that runs against a closed valve, overheats.
  2. Low or unbalanced voltage. Low voltage makes the motor draw more current. On three phase, one weak phase is enough.
  3. The overload is set too low, or the motor is worn. Compare the running current with the nameplate.

Ask for: Pump Control Boxes, Water Pump Repairs

A surface pump keeps losing its prime

  1. A leaking foot valve. The water drains back to the source between runs.
  2. An air leak on the suction side. A loose fitting or a cracked suction pipe lets air in.
  3. The suction lift is too high. A surface pump can only suck water up about 7 to 8 m in practice. Deeper water needs a submersible pump.

Ask for: Booster Pumps, JoJo Tank Pumps, Submersible Pumps

Before you call someone out

  • Note what the pump does and when: at start, after a few minutes, only at night, after rain.
  • Take photos of the control box with its cover on, the pressure switch, the tank and the pump's nameplate if you have it.
  • Note what the gauge reads when the pump starts and when it stops.
  • Find the yield test and the depth the pump hangs at, if you have them.

That lets a technician come with the right parts and often fix it in one visit. Send it with your request below, and see borehole pump repairs for what a repair involves.

Frequently asked questions

Why does my borehole pump keep tripping?
An earth leakage trip usually means water has got into the cable, a joint or the motor. A breaker or overload trip can mean a jammed pump, low voltage or a motor that is overheating. Don't keep resetting it: have the insulation tested.
Can a submersible pump run without a capacitor?
A single phase pump with a separate control box needs its capacitor to start and run, and it will hum without starting if the capacitor fails. Some single phase pumps have the capacitor built in, and three phase pumps need none. See pump spares.
How do I know if my borehole has run dry?
The pump runs but water stops, or comes in spurts with air, and returns after the hole has rested. A technician confirms it by measuring the water level with a dip meter.

More calculators and guides

Free quote request, no obligation

Request borehole pump repairs quotes

Fill in the duty sheet the way a pump technician would: how deep the water is, how high it must go, how much you need, or what has to be pumped away. Pump suppliers, installers and repairers in your area quote you directly.

Pump duty sheetBorehole Pump Repairs
Request
63298
Logged
2026-11-21

1The job

2How many (optional, it helps the quote)

Your ordernot to scale

-
-
-
-
-
-
Estimate
-

A rule of thumb, not a pump selection.

3Power and timing

4Your list (optional)

  1. 01
  2. 02
Up to 12 lines: pumps, boxes, cable, pipe or spares.
Needs and options

5Your details

Free and no obligation. By sending you agree that we may share your request with suitable suppliers, installers and repairers. See our privacy policy.

Get free pump quotes