How the voltage drop is worked out
Every metre of cable has a little resistance, and the motor's current through it loses voltage on the way. The calculator uses the resistance of copper at a working temperature of about 70 °C (0.0206 Ω per metre for 1 mm²):
- Single phase: drop = 2 × current × length × 0.0206 ÷ the cable size in mm² (out and back).
- Three phase: drop = 1.73 × current × length × 0.0206 ÷ the cable size.
This is slightly on the safe side, because it ignores the power factor and the reactance of the cable. If you leave the current at 0, it is estimated from the motor size, assuming an efficiency and power factor typical of small submersible motors. The nameplate figure is always better.
Why it matters on a borehole
- A submersible motor fed through too thin a cable starts slowly, runs hot and draws more current. That shortens its life and trips the protection.
- The length is the whole run: from the board or the control box to the borehole head, and then down to the pump. A pump set at 100 m on a smallholding 150 m from the house is 250 m of cable.
- The installation rules for South Africa (SANS 10142-1) limit the voltage drop between the supply point and the equipment; many pump makers ask for a lower drop for their motors. Ask the installer what limit they design to.
- Joints under water must be made with a proper resin or heat-shrink splice kit, and flat drop cable is made for being in the water.
See pump control boxes for the protection and the wiring, and pump cable and pipe to price the cable.
Frequently asked questions
What size cable do I need for a borehole pump?
Can I use ordinary house wire down the borehole?
Does three phase need thinner cable?
More calculators and guides
- Borehole pump size calculatorTotal head, duty point and a rough motor size from the water level, the lift, the pipe and the flow.
- Pipe friction loss calculatorHead loss in metres and bar, loss per 100 m and the water speed for HDPE and steel pipe.
- Pressure tank size calculatorTank size from the pump flow and the switch settings, with the drawdown, the pre-charge and starts per hour.
- Solar borehole pump calculatorRough solar array, number of panels and daytime flow from the water a day and the total head.
- Tank fill and pump-out time calculatorLitres in a tank, pool, pit or basement, and how long the pump takes to fill or empty it.
- Pump running cost calculatorUnits used and the cost a day, a month and a year at your tariff, and the cost per kilolitre pumped.
- Pump unit converterFlow in m³/h, L/min, L/s and gallons; pressure in bar, kPa, psi and metres of head; kW and hp.
- Pump troubleshooting guideNo water, humming, tripping, short cycling, low pressure or sand: the likely causes and what to check.